Troubleshooting
Air-assist error on Odin Series
Problem description: The machine stops working, and the panel reports Air-assist error. The air pressure value is shown in the figure below. Reasons: 1. The air pressure is too low. If the current air pressure of the machine is lower than the set ...
RF tubes engraving discrepancy problem
Below picture is 5mm acrylic, engraving with 1000mm/s speed, 15% power. Reason: This behavior is not because of a fault. It is due to the fact that the actual output power is with certain fluctuations and is unstable. Solutions: 1. Increase the ...
The RF tube won’t fire the beam?
Problem Description: The RF tube won't fire the beam even the laser switch is on. Reasons: 1. The temperature of RF tube is too high. If the temperature of RF tube is too high, RF tubes won't emit beam. Solution: Please off the machine and wait 4-5 ...