Chiller and Laser Tube
You do not need to remove the tube. It travels just fine in thunder's rigid and strong frame
If you have and RF tube without a chiller or water, you can skip this section
You will need to drain the coolant from the system, then disconnect the 2 water lines and wire between the chiller and laser. use one tube to loop the laser water ports, and the other on the chiller inlet and outlet ports. this will prevent any residual water spilling out and close off the ports so they don't become contaminated. An example of looping the chiller can be seen below
The machine may come packed with foam around the tube. If you can cushion the tube with foam, blanket, etc. Double check that the grub screws on the tube mounts are tight, they are what hold the tube in place. Inspect the tube mounting straps, look for tears or cracks.