Thunder Laser Dual-Stage Air Assist sequencing issues

Thunder Laser Dual-Stage Air Assist sequencing issues

Thunder Lasers with dual-stage air assist systems sometimes experience sequencing issues. This anomaly is predominately occurring when the laser is connected to the PC via USB.


If you toggle air assist ON in LightBurn the high volume stage should activate. If you toggle air assist OFF then that should be the low volume stage. Sometimes this can get out of sequence and work backwards.


Here are the supported workarounds for this issue (#3 is the best solution)



1. Switch the USB communication protocol to Packet instead of Serial. Here's how:



2. Connect via Ethernet like this:


Connecting A Thunder Laser To LightBurn Via Ethernet



3. Use SEND or SHIFT+SEND to initiate the file transfer to the DSP instead of START. When you hit START the job is streamed to the controller. When you press SEND or SHIFT+SEND it transfers the entire file over into the DSP's flash memory. 


When you use SEND the file transfers to the controller and you can go into FILE and run it from the machine. If you hold SHIFT and click SEND it will do the process above but will also initiate the job automatically. So it behaves like SEND :)


Keep in mind that these DSP's have 128M non-expandable memory. SEND methods fill up the memory on the controller so you have to keep the files cleaned up on the controller. You can manage the files from inside LightBurn as well.


    • Related Articles

    • Retrofitting Dual Air Assist

      for Thunder Laser Nova series machines with single air-assist. This is an advanced level installation. Here are all of the resources we have on this: Please see attachment Additional resources: Dual Air Assist Theory of Operation and Schematics How ...
    • Dual-stage Air Assist Sequencing issues

      1. Problem description: The machines are equipped with dual air assist have an issue: Set High blow for job and run the job from software, the air assist on the machine is Low assist channel on. But if you run it from machine, it's normal. 2. ...
    • Selecting between low and high Dual Air Assist stages in LightBurn

      Selecting Between Low and High Dual Air Assist Stages In LightBurn If yours is working backwards please see this article: Thunder Laser Dual-Stage Air Assist Sequencing Issues
    • Dual Air Assist Theory of operation and schematics

      This is a typical installation of the dual stage air-assist in the Nova series machines. Your configuration may differ slightly. The maximum recommended operating system pressure, according to Thunder China Engineering, is now 40 psi to help prevent ...
    • Dual air assist system instructions for use

      Video: