LaserMaker V2.4 Update Details

LaserMaker V2.4 Update Details

1.Removed Features

1. Print

2. File Notes

3. Job Log

4. Export User Log

5. Enter a description to generate images

6. Follow the path with text

7. Thickness Tool
8. Close Curve Tool

9. Marking Processing

10.ArUco Marker

11.Color Separation

12. Zoom Scale

Feature numbers shown in the images below
1-4
5-7
8-9



10
11
12



2.New Features

1.Restructured the parameter library by merging Deep Engraving and Shallow Engraving into a single Engraving mode, improving usability and stability.


2.Added parameter tooltips to the parameter panel. Hovering over a function displays a description of that function.


3.Added Outer Contour extraction to Image Extraction for files uploaded as images. This feature can automatically identify Mark point contours, making it easier to create Mark point designs.

4.During calibration and Mark point processing, the software automatically detects device disconnections and reconnects. The reconnection dialog displays a 10-second countdown; if no action is taken, the process continues reconnecting automatically.

5.Updated the machine type options in the working-area setup for camera calibration: added Nova 24, Nova 35, Nova 51, and Nova 63; removed Odin; and standardized the Bolt series model names.

6.Pressing Esc while drawing a straight line or curve now ends and completes the drawing.

3.Feature Improvements

1.Added guidance for first-time users of Mark point processing. To view the guidance again during subsequent jobs, click View guide in the upper-right corner.

2.Enhanced Mark point positioning with support for saving and matching multiple templates. 

After a Mark point design has been used for the first time, its settings can be restored for subsequent jobs. Clicking Yes in the settings recovery dialog takes the user directly to the Start Processing step.
Jobs can now be stopped during processing.


3.Improved the wording of error dialogs to help users identify problems.

4.Resolved various issues that caused the software to freeze or crash.

5.Improved connection speed for devices connected via Wi-Fi or USB, and fixed slow canvas loading caused by connection issues.

6.Improved the Font tool: it opens faster when a design contains a large amount of text, and font groups are displayed more clearly.

7.Resolved file compatibility issues with the legacy parameter library. Version 2.4 supports designs exported from earlier versions.

8.Improved object selection on the canvas. 

Prioritize selecting smaller objects when overlapping.Allow objects to be dragged directly from within their boundaries.
Engraving fills are now displayed behind Cutting/Scoring outlines so that the outlines remain visible.


9.Completed translations into 10 languages for the parameter library.

4.Bug Fixes

1.If the software freezes under abnormal conditions, an Auto-recovery dialog appears after the software is closed and reopened, allowing affected files to be recovered.

2.Fixed issues that prevented legacy .lcpx project files, including those saved in versions 2.3.2 and 2.3.3, from opening or caused the software to freeze after import.

3.Fixed an issue that prevented non-administrator Windows accounts from sending files to the device. Previously, on computers with multiple accounts, only the administrator account could send files.

Fixed an issue that prevented power and speed settings from being changed on the machine controller after a file had been sent.

4. Fixed file import and export issues: 

DXF import errors of up to 0.1 mm; failure to open DXF files containing images; 

color changes in CMYK images imported from PDF files; a single circle in an AI file being interpreted as two separate circles; and slow DXF export.

5. Fixed several macOS issues, including an empty parameter library on first launch, an “Unknown error” message when activation expired, and a maximized window that did not fill the screen.

6. Fixed several issues in the Titan calibration workflow:

Inability to switch between standard-lens and fisheye-lens calibration files; full-frame preview misalignment when manual calibration followed automatic calibration;

the movable camera view remaining visible when its calibration step was skipped; exposure adjustments being applied to other cameras, causing overexposure or underexposure; and a progress dialog that could not be closed after Mark point calibration failed.

7. Fix issues with using the Eraser toolbox and Cutting leads.

Fixed circle deformation caused by the Trim and Break functions in the Eraser toolbox.
Fixed reversed behavior in the Internal and External cutting lead options, where selecting External incorrectly produced an internal lead.



8. Clarified the distinction between Reprocess Current Material and Process New Material in Mark point processing to make the two buttons easier to understand. Also,Mark point calibration for the movable camera must be completed before clicking “Send” to enter the processing interface. A pop-up message displays the full sequence of steps required.

9. Fixed an issue in Mark point processing where using Reprocess Current Material displayed an “Exceeds working area”message and prevented the machine from returning to the zero position.